Importing Measurement Data

REW can import frequency response and impedance measurement data from other applications, including the ETF5 measurement system (http://www.acoustisoft.com). Most ETF5 export formats are supported, along with generic comma, space or TAB-delimited text files. Note that when making measurements with ETF5 it is best to use the calibrated SPL option to allow level comparisons between channels.

ETF *.pcm Format Impulse Responses

Full range ETF measurements allow the impulse response to be exported in a .pcm raw data format, using the File → Write Impulse As *.pcm option. Use REW's File → Import Impulse Response command to load these files. Importing the impulse response allows REW's Spectral Decay and Waterfall plots to be generated from the data (this is not possible when importing frequency response text files). REW loads the first 128k samples from the file (approx 2.73s at 48k sampling).

WAV, AIFF, Flac or MP3 Format Impulse Responses

The File → Import Impulse Response command can also be used to load impulse responses that have been saved as .wav, .aiff, .mp3 or .flac format. REW can load up to approx 60 seconds of data from the file.

Frequency Response and Impedance Text Files

The File → Import Frequency Response and File → Import Impedance Measurement commands accept text files with extension .txt, .frd, .dat or .zma. If the extension is .zma the data is always treated as impedance, otherwise it is treated as SPL if loaded via Import Frequency Response or impedance if loaded via Import Impedance Measurement. The following formats are accepted:

Comma-delimited File Format

Here is an example of a valid format for comma-delimited SPL data without phase:

            SPL measurements acquired by REW V3.08
            Source: D:\REW\test files\testfile.txt
            Format: Comma delimited data
            Dated: 05-Mar-2005 17:53:56
            Channel: Left, Bass limited 80Hz

            20.0, 65.01
            21.0, 65.77
            22.0, 67.50
            23.0, 67.93
            24.0, 68.22
            25.0, 67.88
            26.0, 67.92
            27.0, 68.31, this line has a comment
            28.0, 69.14
            29.0, 69.16
            30.0, 69.29
        

If comma is used as the decimal delimiter in your locale it is best for clarity to use TAB, space or semicolon as the separator.

Space-delimited File Format

Here is some impedance data in space-delimited format, with phase

            * Measurement data saved by REW V5.00
            * Source: Line (ESI MAYA44 Audio), no input selected, Right channel, volume: no control
            * Format:   1M Log Swept Sine, 1 sweep at -30,0 dBFS
            * Dated: 31-Dec-2010 11:26:49
            * Sense Resistor: 100.0
            * Lead resistance: 0.000
            * Calibration factor: 1.0028
            * Note: horizontal
            * Measurement: SPH170 horz
            * Frequency Step: 0.36621094 Hz
            * Start Frequency: 1.8310547 Hz
            *
            * Freq(Hz) Z(Ohms) Phase(degrees)
            1.831 6.423 5.392
            2.197 6.444 6.426
            2.563 6.481 7.302
            2.930 6.522 8.049
            3.296 6.558 8.714
            3.662 6.586 9.368
            4.028 6.609 10.076
            4.395 6.632 10.864
            4.761 6.664 11.706
            5.127 6.705 12.549
            5.493 6.753 13.346
            5.859 6.803 14.082
            6.226 6.851 14.777
            6.592 6.896 15.467
            6.958 6.939 16.180
            7.324 6.985 16.919
            7.690 7.034 17.669
            8.057 7.089 18.409
            8.423 7.147 19.126
            8.789 7.207 19.822
            9.155 7.269 20.505
            9.521 7.332 21.181
            9.888 7.398 21.851
        
Help Index